- Home
- Equipment
Refine by
Pid Analyzers Environmental Equipment & Supplies
30 equipment items found
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
Applications-Indoor air quality: Two Models. No pump- diffusion. Battery 9VDC (P) or Line operated (F). Technique- Dual wavelength IR. Internal Memory:> 2,000 points. Display: bright OLED. Controls: On/Off & Com switch. Range: 0-5,000 ppm CO2. Size: 3”W x 4 5/8” L x 1“ T. Weight: 0.25 #. Communication: WiFi to PC or Server, RS232. Starting at $295.00. Data collection on ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The far ultraviolet detector (FUV) is a nearly universal detector with ppb detection limits. The detector is described below: The Model 54 has a UV lamp (10.6eV), a UV photodiode, a HV power supply for the photodiode bias, and a logarithmic electrometer. The electrometer output is 0-10 VDC. The customer needs a separate ADC channel to feed the electrometer signal into the GC’s data system. ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The thermal conductivity detector (TCD) is a universal detector with a ppm to % level range. The detector is described below: The Model 55 has a thermal conductivity (TCD) cell with a sealed reference, a low voltage power supply, and a Wheatstone bridge with an electrometer. The electrometer output is 0-10 VDC. The customer needs a separate ADC channel to feed the electrometer signal into the ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The flame photometric detector (FPD) is used for the selective measurement of any S or P species that can be burned in a flame to product chemiluminescence. This corresponds to either small molecules like H2S or PH3 or large pesticides containing S or P. The detector is described below: The Model 56 has an FPD (burner), a photomultiplier tube (PMT), a HV power supply for the PMT, an interference ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 1000 is a low cost continuous Analyzer. There are a number of sensors 30+ EC, CG & TCD. It has an optional 4-20 mA output, a single programmable setpoint, larger pump & an industrial NEMA 4 enclosure. This 1000 has a variety of sensors to chose from (>40) and comes with an Operator's Manual, configuration software and RS232 ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 201C is a continuous VOC Analyzer designed for continuous or process control. It has optional 4-20 mA output, RS485, MODBUS, 2-4 programmable setpoints, larger pump, bypass flow & and a 19” rack or industrial wall mount NEMA 4 enclosure. This 201C has the choice of one 9.5 or 10.6 eV lamp in a PID or an FID, Operator's Manual, configuration software and RS232 cable. The ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 204 is a continuous TCD Analyzer designed for continuous or process control. It has optional 4-20 mA output, RS485, MODBUS, 2-3 programmable setpoints, larger pump, bypass flow & and a 19'' rack or industrial wall mount NEMA 4 enclosure. This 204 has a rugged TCD with a sealed reference cell, Operator's Manual, configuration software and RS232 cable. The detector is the ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 115 is an FID based Analyzer for measuring total hydrocarbons including methane to 50,000 ppm. It has enhanced features such as a faster response time, extended linear range and datalogging (see below). The 115 includes the choice of one (1) Snap-On Module with FID, Operator's Manual, and Rechargeable Nickel Metal Hydride ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 30 is an analyzer for the measurement of toxic gases in the workplace. This analyzer is unusual since it is easy to calibrate, has a fast response and has only one step to send logged (optional) data to a PC. It uses electrochemical sensors for the measurement of ppb to ppm levels of selected toxics. It has many unique features. H2S, HCN, PH3, AsH3 ETO, NH3, CH2O, Cl2, O3, CH3SH. O2, ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 102 is a considerably upgraded replacement for our Model PI101, HW101, DL101, 101N, & IS101; It has enhanced features such as a faster response time, extended range, elimination of any moisture sensitivity, capability of having up to 4 sensors plus a ppb range, and improvements such as a pump & datalogging (see below). The Model 102 Snap-On PID™ Photoionization Analyzer is ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The photoionization detector (PID) is used for the measurement of low (ppb) organic and inorganic species that can be ionized by the UV lamp (9.5, 10.6 & 11.7). Nearly 20,000 of these detectors have been sold worldwide since it was first released by HNU Systems in 1976. It has been used for the measurement of VOC’s in water (EPA method 602, EPA Method 50--, EPA Method SW846…, ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 113+ is a EC based Analyzer that can measure up to ppm to% v/v of components and has the capability to add up to 2 EC sensors and a CG or TCD sensor. The Model 113 includes the choice of one Snap-On Module plus up to 1-3 optional electrochemical sensors an an optional TCD or CG sensor , datalogging, Operator's Manual, and Rechargeable Nickel Metal Hydride ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 114 is an IR based analyzer that utilizes interchangeable IR sensors (for CO2 and CH4) for low range or high range (0-100% v/v). The Model 114 includes one IR sensor for CH4 or CO2 with up to 3 optional electrochemical sensors, datalogging, Operator's Manual, and Rechargeable Nickel Metal Hydride Battery. The main application is checking the composition of landfill ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
Model 102+ Photoionization (PID) Analyzer for VOC’s (0-500 & 0-5000 ppm) +4 sensors- 6 Channel PID. Technologies: Photoionization (9.5, 10.0, 10.6, 11,7 eV ppm), Infrared CO2, CH4, Electrochemical- PID + 4 sensors- 6 Channel PID analyzer with optional ppb ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 301-C PGCs are flexible and versatile Analyzers that are in their fourth generation. The addition of these new Analyzers greatly improves the capability and range of Process Analyzers from ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
Model 102a Photoionization (PID) Analyzer for VOC's (0-500 & 0-5,000 ppm) ppm PID Only- with ppb Option. Technologies: Photoionization (9.5, 10.0, 10.6, 11,7 eV ppm) PID Only , with optional ppb ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The flame ionization detector (FID) is used for the selective measurement of any organic species that can be ionized in a flame. This corresponds to most hydrocarbons and is described below: The Model 53 has an FID (burner with HV bias and collector), a power supply for the FID bias, an electrometer and gauges and flow control for the support gases for the FID. The electrometer output is 0-10 ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
Model 33W- Arsenic in Water (no organics) Tap water, well water or bottled water that does not contain volatile organic compounds does not need a GC for removal of VOC’s from the AsH3 peak so a GC is not needes and this version is less expensive. ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 112 is a low cost continuous VOC Analyzer. It has an optional 4-20 mA output, a single programmable setpoint, larger pump & an industrial NEMA 4 enclosure. This 112 the choice of one 9.5 or 10.6 eV lamp, Operator's Manual, configuration software and RS232 ...
Manufactured by:PID Analyzers, LLC based inSandwich, MASSACHUSETTS (USA)
The Model 202 is a low cost continuous IR Analyzer. It has an optional 4-20 mA output, a single programmable setpoint, larger pump & an industrial NEMA 4 enclosure. This 202 has the choice of one or more CH4, CO2, CO, N2O or, refrigerant gas sensor, Operator's Manual, configuration software and RS232 ...
